Flameguard Fire Protection Philippines Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from Flameguard Fire Protection Philippines, Fire protection service, 50 Holy Spirit Drive, Don Antonio Heights 2, Holy Spirit, Quezon City.

Helping property managers ensure fire safety and compliance | NFPAยฎ Certified engineer specializing in fire protection maintenance and installations | Managed fire safety for 70+ high-rise residential properties.

02/09/2026

Saan ba dapat binabase ang cut-in at cut-out ng jockey pump?

28/08/2026

AKO NAMAN MUNA PLEASE! ๐Ÿฅน

๐—ž๐—ฎ๐—ถ๐—น๐—ฎ๐—ป๐—ด๐—ฎ๐—ป ๐—ฏ๐—ฎ ๐˜๐—ฎ๐—น๐—ฎ๐—ด๐—ฎ๐—ป๐—ด ๐—ถ-๐—ฟ๐—ฒ๐—ณ๐—ถ๐—น๐—น ๐—ฎ๐—ป๐—ด ๐—ณ๐—ถ๐—ฟ๐—ฒ ๐—ฒ๐˜…๐˜๐—ถ๐—ป๐—ด๐˜‚๐—ถ๐˜€๐—ต๐—ฒ๐—ฟ ๐˜๐—ฎ๐—ผ๐—ป-๐˜๐—ฎ๐—ผ๐—ป?Common practice ang annual refilling ng fire extinguisher...
26/08/2026

๐—ž๐—ฎ๐—ถ๐—น๐—ฎ๐—ป๐—ด๐—ฎ๐—ป ๐—ฏ๐—ฎ ๐˜๐—ฎ๐—น๐—ฎ๐—ด๐—ฎ๐—ป๐—ด ๐—ถ-๐—ฟ๐—ฒ๐—ณ๐—ถ๐—น๐—น ๐—ฎ๐—ป๐—ด ๐—ณ๐—ถ๐—ฟ๐—ฒ ๐—ฒ๐˜…๐˜๐—ถ๐—ป๐—ด๐˜‚๐—ถ๐˜€๐—ต๐—ฒ๐—ฟ ๐˜๐—ฎ๐—ผ๐—ป-๐˜๐—ฎ๐—ผ๐—ป?

Common practice ang annual refilling ng fire extinguishers, pero hindi ibig sabihin na kailangan itong i-refill o palitan automatically dahil one year na ang lumipas.

Under the Fire Code of the Philippines, the maintenance of portable fire extinguishers follows NFPA 10.

Hindi required ang annual refilling kung maayos pa ang condition ng extinguisher. Refilling is needed kapag:

๐Ÿ”บ Nagamit na ang fire extinguisher
๐Ÿ”บ Nabawasan o nawala ang extinguishing agent
๐Ÿ”บ May pressure loss
๐Ÿ”บ May indication ng leakage

Maaaring i-check ang condition nito through its weight and pressure, depending on the type of extinguisher.

Aside from refilling, mayroon ding required maintenance intervals. For common dry chemical and halogenated agent fire extinguishers, internal inspection is generally required every six years, as applicable.

Pero kahit hindi kailangan ng annual refill, monthly external or visual inspection is still required para ma-check kung:

๐Ÿ”บ Nasa proper location at accessible ang extinguisher
๐Ÿ”บ May physical damage
๐Ÿ”บ May signs of leakage
๐Ÿ”บ Nasa proper range ang pressure
๐Ÿ”บ May ibang visible condition na maaaring makaapekto sa paggamit nito

May guidance din mula sa BFP regarding annual refilling. Under BFP Memorandum Circular 2016-16, prohibited sa BFP personnel ang pag-require ng annual refilling ng portable fire extinguishers for FSIC purposes kung ang extinguisher ay nasa good condition pa.

Kaya tandaan, hindi dahil one year na ang fire extinguisher, kailangan na agad itong i-refill. Ang actual condition at required maintenance ng extinguisher ang dapat maging basis.

Want a copy of the BFP memo? Comment โ€œFire Extinguisher Memoโ€ and weโ€™ll send it to your inbox.

๐—ฆ๐—ฎ๐—ฏ๐—ฎ๐˜†-๐˜€๐—ฎ๐—ฏ๐—ฎ๐˜† ๐—ฎ๐—ป๐—ด ๐—ฎ๐—ฝ๐—ฝ๐—น๐—ถ๐—ฎ๐—ป๐—ฐ๐—ฒ๐˜€ ๐˜€๐—ฎ ๐—ถ๐˜€๐—ฎ๐—ป๐—ด ๐—ฒ๐˜…๐˜๐—ฒ๐—ป๐˜€๐—ถ๐—ผ๐—ป ๐—ฐ๐—ผ๐—ฟ๐—ฑ? Common setup ito sa bahay at office, pero safe ba talaga?Dalawa sa c...
24/08/2026

๐—ฆ๐—ฎ๐—ฏ๐—ฎ๐˜†-๐˜€๐—ฎ๐—ฏ๐—ฎ๐˜† ๐—ฎ๐—ป๐—ด ๐—ฎ๐—ฝ๐—ฝ๐—น๐—ถ๐—ฎ๐—ป๐—ฐ๐—ฒ๐˜€ ๐˜€๐—ฎ ๐—ถ๐˜€๐—ฎ๐—ป๐—ด ๐—ฒ๐˜…๐˜๐—ฒ๐—ป๐˜€๐—ถ๐—ผ๐—ป ๐—ฐ๐—ผ๐—ฟ๐—ฑ?

Common setup ito sa bahay at office, pero safe ba talaga?

Dalawa sa common risks nito ay overloading at loose connections. Kapag masyadong maraming high-load appliances ang nakakabit sa isang extension cord, maaaring lumampas ang current sa kaya ng wire. This causes heat buildup that can eventually damage or melt the insulation.

Loose plugs, sockets, and adapters can also generate excessive heat. Mas tumataas pa ang risk kapag low-quality o hindi safety-certified ang extension cord at chargers na ginagamit.

Para maiwasan ito:

๐Ÿ”บ Huwag pagsabay-sabayin sa isang extension cord ang high-load appliances gaya ng plantsa, microwave, at aircon.
๐Ÿ”บ Gumamit lamang ng quality at properly certified electrical products. Hanapin ang ICC sticker o PS Mark bilang patunay na dumaan ito sa tamang product certification.
๐Ÿ”บ Iwasang gamitin ang maluluwag na plugs, sockets, at adapters.
๐Ÿ”บ Ipa-design o ipa-check ang electrical system sa qualified electrical professional, tulad ng electrical engineer o master electrician.

Kung may electrical fire at safe itong gawin, disconnect the power first before using the appropriate Class C fire extinguisher.

Extension cords are useful, pero hindi dapat ito gawing permanenteng kapalit ng properly designed electrical system.

Share this to your family and friends para maiwasan ang overloading at unsafe wiring practices.

Nagpapaputok pa rin ba kayo ng sprinkler head tuwing fire drill o testing?Mukhang magandang paraan ito para ipakitang gu...
19/08/2026

Nagpapaputok pa rin ba kayo ng sprinkler head tuwing fire drill o testing?

Mukhang magandang paraan ito para ipakitang gumagana ang sprinkler system. Pero hindi ito ang recognized testing method sa NFPA 13, NFPA 25, o Fire Code of the Philippines.

Hindi rin accurate na fire simulation ang direktang pagsindi ng apoy sa ilalim ng sprinkler. Sa actual fire, ang sprinkler ay naa-activate dahil sa init na naiipon at gumagalaw sa ilalim ng kisame, hindi dahil may apoy na nakatutok mismo sa sprinkler head.

Para i-simulate ang operation ng sprinkler system, ginagamit ang inspectorโ€™s test connection (ITC) o proper test and drain assembly. Dinisenyo ito para gayahin ang flow ng isang operating sprinkler nang hindi kailangang magsakripisyo ng sprinkler head.

At kung listed ang bagong sprinkler, factory-tested na rin ito bago makarating sa project.

Kaya sa susunod na fire drill o testing, gamitin ang tamang test connection. Hindi kailangang gawing action scene ang sprinkler. ๐Ÿ˜…

May fire drill bang naka-schedule sa building ninyo? I-share ito sa building management o safety officer.

14/08/2026

Pwedeng wala ng floor control valve?

13/08/2026

Mali ang sprinkler head? 1990s pa lang pala ay required na ito.

11/08/2026

Bakit eccentric reducer ang gamit sa suction ng fire pump?

06/08/2026

Ano ang pinagkaiba ng fire suppression at fire extinguishing?

Address

50 Holy Spirit Drive, Don Antonio Heights 2, Holy Spirit
Quezon City
1127

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm
Saturday 8am - 12pm

Telephone

+639567641655

Website

Alerts

Be the first to know and let us send you an email when Flameguard Fire Protection Philippines posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Organization

Send a message to Flameguard Fire Protection Philippines:

Shortcuts

Share